Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Modello: HLG-150H
marchio: Meanwell
Pacchetto: Scatola
produttività: 20000pcs per month
Trasporti: Ocean,Land,Air
Luogo di origine: Guangdong, Cina
Supportare: 5000pcs per month
Porta: Shenzhen,Guangzhou,Hongkong
Tipo di pagamento: T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CIF
Alimentatore LED impermeabile HLG-150H Meanwell
Descrizione dei prodotti
Alimentatore switching a singola uscita da 150 W impermeabile , il seguente modello ampiamente utilizzato con Iseeled `s condotto le lampade, GAL-150 H - 12, HLG-150 H -1 5, HLG-150 H -24, ecc qualche altro modello per lampade speciali con diversa tensione di ingresso.
HLG-150 H -12 Blank: IP67 nominale. Cavo per connessione I / O.
HLG-150 H -12A: grado di protezione IP65. La tensione di uscita e il livello di corrente costante possono essere regolati tramite il potenziometro interno.
HLG-150 H -12B: IP67 valutato. Livello corrente costante regolabile tramite cavo di uscita con segnale 1 ~ 10Vdc o PWM o resistenza.
HLG-150 H -12D (opzionale): IP67. Funzione di oscuramento del timer, contattare MEAN WELL per i dettagli.
Model |
HLG-150H-12 |
HLG-150H-15 |
HLG-150H-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
|||
7.5-12.5A |
6-10A |
3.8-6.3A |
||
RATED POWER |
150W |
150W |
151.2W |
|
VOLTAGE ADJ. RANGE |
10.8-13.5V |
13.5-17V |
22-27V |
|
Input |
Voltage Range |
90-264VAC 127-370V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
92% |
92.5% |
93.5% |
|
AC CURRENT (Typ.) |
1.7A / 115VAC 0.75A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14-17V |
18-21V |
28-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
100 ℃ up or less10 ℃ (RTH2) |
|||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down |
||||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
192.2K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
228*68*38.8mm (L*W*H) |
|||
PACKING |
1.15Kg; 12pcs/14.8Kg/0.8CUFT |
|||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Type A only. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. |
1. Tutti i parametri NON espressamente menzionati sono misurati a 230 VAC di ingresso, carico nominale e 25 di temperatura ambiente. Nota
2. Ripple e rumore sono misurati a 20 MHz di larghezza di banda utilizzando un cavo a doppino intrecciato da 12 "terminato con un condensatore parallelo 0.1uf e 47uf.
3. Tolleranza: include la tolleranza di impostazione, la regolazione della linea e la regolazione del carico.
4. La riduzione può essere necessaria con tensioni di ingresso basse. Si prega di verificare le caratteristiche statiche per maggiori dettagli.
5. Digitare solo A.
6. La sicurezza e la progettazione EMC fanno riferimento a EN60598-1, CNS15233, GB7000.1, FCC part18.
7. La durata del tempo di allestimento viene misurata al primo avvio a freddo. L'attivazione / disattivazione dell'alimentazione può comportare un aumento del tempo di impostazione.
8. L'alimentazione è considerata un componente che verrà utilizzato in combinazione con l'apparecchiatura finale. Dal momento che le prestazioni EMC saranno influenzate dal installazione completa, i produttori di apparecchiature finali devono riqualificare di nuovo la direttiva EMC sull'installazione completa.
9. Fare riferimento alla dichiarazione di garanzia.Elenco prodotti : Accessori LED > Alimentatore impermeabile Meanwell
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.